Standard Features
  • 316L Stainless Steel on all Wetted Surfaces
  • Built in accordance with A.S.M.E. Miniature Boiler Code
  • UL Listed and labeled under UL 834
  • Dual Pressure Controls (UL 353)
  • High Pressure Safety Reset. (UL 353)
  • Low Level Cut-Off (LLCO)
  • Safety Relief Valve (A.S.M.E. Section I - V-Stamp)

Recommended Options (Non-Standard)
  • Spare Parts Package
  • Single Service Transformer
Unit of Measure
Items
S.S. LB 40-60 Electric Steam Generators

40 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

S.S. LB 40-60 Electric Steam Generators

50 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

S.S. LB 40-60 Electric Steam Generators

60 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

S.S. LB 40-60 Electric Steam Generators

40 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

S.S. LB 40-60 Electric Steam Generators

50 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator
Description N/A Standard Features
  • 316L Stainless Steel on all Wetted Surfaces
  • Built in accordance with A.S.M.E. Miniature Boiler Code
  • UL Listed and labeled under UL 834
  • Dual Pressure Controls (UL 353)
  • High Pressure Safety Reset. (UL 353)
  • Low Level Cut-Off (LLCO)
  • 15 psi Safety Relief Valve (A.S.M.E. Section I - V-Stamp)

Recommended Options (Non-Standard)
  • Spare Parts Package
  • Single Service Transformer
Brands N/A Electro-Steam™
Electrical Power Rating N/A 40 kW N/A 50 kW N/A 60 kW N/A 40 kW N/A 50 kW
Power Supply Voltage1 N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC
Phase N/A 3
Note for Phase N/A Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request. N/A Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request. N/A Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request. N/A N/A
Frequency N/A 50 Hz60 Hz
Boiler Horse Power N/A 4.00 bhp N/A 5.00 bhp N/A 6.00 bhp N/A 4.00 bhp N/A 5.00 bhp
Steam Capacity2 N/A 138.00 lb/hr62.60 kg/h N/A 172.50 lb/hr78.24 kg/h N/A 207.00 lb/hr93.89 kg/h N/A 138.00 lb/hr62.60 kg/h N/A 172.50 lb/hr78.24 kg/h
Water Consumption N/A 16.54 gal/h62.60 L/h N/A 20.67 gal/h78.24 L/h N/A 24.80 gal/h93.89 L/h N/A 16.54 gal/h62.60 L/h N/A 20.67 gal/h78.24 L/h
Note for Water Consumption N/A N/A N/A N/A Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF. N/A Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
Gross British Thermal Units (BTU) Output N/A 133901 Btu/hr N/A 167377 Btu/hr N/A 200852 Btu/hr N/A 133901 Btu/hr N/A 167377 Btu/hr
Maximum Boiler Pressure N/A 100 psi N/A 100 psi N/A 100 psi N/A 15 psi N/A 15 psi
Operating Pressure N/A 0 to 80 psi N/A 0 to 80 psi N/A 0 to 80 psi N/A 0 to 11 psi N/A 0 to 11 psi
Note for Operating Pressure N/A Factory Set at 80 psi N/A Factory Set at 80 psi N/A Factory Set at 80 psi N/A N/A
Maximum Boiler Capacity N/A 15 gal
Boiler Fill Capacity N/A 11 gal
Boiler Material3 N/A 316L Stainless Steel
Cabinet Material N/A 304 Stainless Steel
Plumbing Material N/A 316L Stainless Steel (Schedule 40)
Industry Standards N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Underwriters Laboratories (UL) Canadian Underwriters Laboratories (cUL)
Amperage at 208 VAC (3Ø Phase) N/A 111.00 A N/A 138.80 A N/A 166.50 A N/A 111.00 A N/A 138.80 A
Amperage at 208 VAC (3Ø Phase) Per Box N/A 104.80 A N/A 131.00 A N/A 157.20 A N/A N/A
Amperage at 240 VAC (3Ø Phase) N/A 60.80 A N/A 76.00 A N/A 91.20 A N/A 104.80 A N/A 131.00 A
Amperage at 240 VAC (3Ø Phase) Per Box N/A 55.60 A N/A 69.60 A N/A 83.50 A N/A N/A
Amperage at 380 VAC (3Ø Phase) N/A 52.50 A N/A 65.60 A N/A 78.70 A N/A 60.80 A N/A 76.00 A
Amperage at 380 VAC (3Ø Phase) Per Box N/A 48.10 A N/A 60.10 A N/A 72.20 A N/A N/A
Amperage at 415 VAC (3Ø Phase) N/A 38.50 A N/A 48.10 A N/A 57.70 A N/A 55.60 A N/A 69.60 A
Amperage at 440 VAC (3Ø Phase) N/A N/A N/A 78.70 A N/A 52.50 A N/A 65.60 A
Amperage at 480 VAC (3Ø Phase) N/A N/A N/A N/A 48.10 A N/A 60.10 A
Amperage at 600 VAC (3Ø Phase) N/A N/A N/A N/A 38.50 A N/A 48.10 A
Length N/A 52 in
Width N/A 26 in
Height N/A 36 in
Total Length N/A 96 in
Total Width N/A 58 in
Total Height N/A 45 in
Water Inlet N/A 1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS)
Steam Outlet N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS
Safety Valve N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces) , Brass Body N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces) , Brass Body N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces) , Brass Body N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body. N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body.
Drain N/A 1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS)
Spare Parts Package Includes N/A
  • 18-Month Warranty (12-Month Standard)
  • (2) Electric Heaters and (2) Heater Gaskets
  • (2) Sight Glass Tubes and (4) Washers
  • (1) Pressure Control
  • (1) Contactor
Single Service Transformer N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. N/A Supplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC 1Ø for the controls; with the option, only the one (1) primary high voltage supply is required. N/A Supplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC 1Ø for the controls; with the option, only the one (1) primary high voltage supply is required.
Manual Low Water Reset4 N/A Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production.
Portable Mounting Includes N/A
  • Wheels
  • Push Handle
  • Single Service Transformer Option
Water Feed Booster Pump N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. N/A The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. N/A The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm.
  • 1 Each Electro-Steam™ electric steam generator requires two (2) power supplies: One (1) primary high voltage supply and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate only one (1) customer specific high voltage supply for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
  • 2 Calculations are based off of a 212 ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60 ºF and 140 ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140 ºF.
  • 3 Wetted Surfaces.
  • 4 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply remove the jumper wire from the back of the Reset Button.