S.S. LB 40-60 Electric Steam Generators
S.S. LB-40 (L) 40 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator
Standard Features
| 316L Stainless Steel on all Wetted Surfaces | ASME Certified |
| High Pressure Safety Reset | UL Listed and labeled under UL 834 |
| Dual Pressure Controls (UL 353) | Low Level Cut-Off (LLCO) |
| Safety Relief Valve possessing the ASME V Mark |
Recommended Options (Non-Standard)
| Spare Parts Package | Single Service Transformer |
Specifications
| Brand | Electro-Steam™ |
|---|---|
| Variant | Low Pressure |
| Electrical Power | 40 kW |
| Power Supply Voltage1 | 208 VAC, 230 VAC, 380 VAC, 415 VAC, 440 VAC, 480 VAC, 600 VAC |
| Phase | 3 |
| Frequency | 50 Hz, 60 Hz |
| Boiler Horse Power | 4.0 bhp |
| Steam Capacity2 | 138.0 lb/hr (62.60 kg/hr) |
| Water Consumption3 | 16.54 gal/hr (62.61 L/hr) |
| Gross British Thermal Units (BTU) Output | 133,901 Btu/hr |
| Maximum Boiler Pressure | 15 psi |
| Operating Pressure | 0 to 11 psi |
| Maximum Boiler Capacity | 15 gal |
| Boiler Fill Capacity | 11 gal |
| Boiler Material4 | 316L Stainless Steel |
| Cabinet Material | 304 Stainless Steel |
| Plumbing Material | 316L Stainless Steel (Schedule 40) |
Amperage by Voltage (3Ø Phase)
| 208 VAC | 240 VAC | 380 VAC | 415 VAC | 440 VAC | 480 VAC | 600 VAC |
|---|---|---|---|---|---|---|
| 111.00 A | 104.80 A | 60.80 A | 55.60 A | 52.50 A | 48.10 A | 38.50 A |
Plumbing Connection Sizes
| Water Inlet | 1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS) |
|---|---|
| Steam Outlet | 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS |
| Safety Valve | 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body. |
| Drain | 1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) |
Options
| Spare Parts Package Includes | 18-Month Warranty (12-Month Standard) (2) Electric Heaters and (2) Heater Gaskets (2) Sight Glass Tubes and (4) Washers (1) Pressure Control (1) Contactor |
|---|---|
| Single Service Transformer | Supplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC1Ø for the controls; with the option, only the one (1) primary high voltage supply is required. |
| Manual Low Water Reset5 | Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. |
| Portable Mounting Includes | Wheels Push Handle Single Service Transformer Option |
| Water Feed Booster Pump | The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. |
- 1 Each Electro-Steam™ electric steam generator requires two (2) power supplies: One (1) primary high voltage supply and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate only one (1) customer specific high voltage supply for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
- 2 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
- 3 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
- 4 Wetted Surfaces.
- 5 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply remove the jumper wire from the back of the Reset Button.