- DTV KIT (Drain Tempering Kit)
- The Drain Tempering Kit is an optional accessory meant to be integrated into one of Electro-Steam's electric steam generator systems. It is designed to temper (cool) the hot discharge (effluent) from the generator to meet plumbing code requirements and prevent damage to drain piping.
- Learn more about the Drain Tempering Kit →
- MAFD (Motorized Automatic Flush And Drain)
- Opens the water inlet solenoid and actuated drain valve for 3 minutes on start-up to allow solids in the water and vessel to drain from the unit reducing scale build-up in the pressure vessel.
- Water Level Float (40kw+)
- An option that replaces the probe type water level sensors on units 40kW or larger.
- 5 Micron Water Filter
- Filters particles of 5 microns or greater from the incoming feed water source. Helps reduce solids build-up in the pressure vessel.
- Manual Reset Low Water
- Changes the automatic low water reset to a manual version that requires an operator to physically reset the unit with a button press on the generator.
- Single Phase (30kw & Lower)
- A no-charge option that allows the unit to operate on a single-phase voltage of 208V or greater electrical supply, when 3 phase isn't available.
- Single Service Transformer
- Steps down a portion of the 3 phase voltage to run the 120v control circuit on the boiler. This replaces the need to have a separate 120v supply to the unit.
- Condensate Return Tank For (H) (LB) / Condensate Return Tank For (L) (LB)
- These float modulated holding tanks are unit mounted, pre-plumbed to the water inlet and calibrated to allow returned condensate to be cooled and mixed with fresh feedwater, preserving resources and making the unit more efficient to operate.
- Dual Operating Pressures
- This option allows the operator of the steam generator to toggle between two set operating pressures without having to manually adjust the unit's pressure controls.
- Step Sequencer (40kw And Above)
- Delays the all-on, all-off engagement of the unit's heating elements and breaks the sequence down into steps to lessen the chances of breaker tripping when the unit builds operating pressure.
- Remote On/off
- Allows the operator to connect to a relay in the electrical panel to facilitate remote operation of the unit from a different location such as a control room or workstation.
- Remote Indicator Signal/Alarm Signal
- Sends a signal via relay in the electrical panel to alert operators to a variety of conditions.