S.S. LB 40-60 Electric Steam Generators

S.S. LB-60 (L) 60 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

S.S. LB-60 (L), 60 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

Dimensions

Length52 in
Width26 in
Height36 in

Minimum Clearance

Total Length96 in
Total Width58 in
Total Height45 in

Industry Standards

  • American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code
  • American Society of Mechanical Engineers (ASME) - CSD-1
  • Canadian Underwriters Laboratories (cUL)
  • Underwriters Laboratories (UL)
ASME UL Listed

Standard Features

316L Stainless Steel on all Wetted Surfaces ASME Certified
High Pressure Safety Reset UL Listed and labeled under UL 834
Dual Pressure Controls (UL 353) Low Level Cut-Off (LLCO)
Safety Relief Valve possessing the ASME V Mark

Recommended Options (Non-Standard)

Spare Parts Package Single Service Transformer

Specifications

BrandElectro-Steam™
VariantLow Pressure
Electrical Power60 kW
Power Supply Voltage1208 VAC, 230 VAC, 380 VAC, 415 VAC, 440 VAC, 480 VAC, 600 VAC
Phase3
Frequency50 Hz, 60 Hz
Boiler Horse Power6.0 bhp
Steam Capacity2207.0 lb/hr (93.89 kg/hr)
Water Consumption324.8 gal/hr (93.88 L/hr)
Gross British Thermal Units (BTU) Output200,852 Btu/hr
Maximum Boiler Pressure15 psi
Operating Pressure0 to 11 psi
Maximum Boiler Capacity15 gal
Boiler Fill Capacity11 gal
Boiler Material4316L Stainless Steel
Cabinet Material304 Stainless Steel
Plumbing Material316L Stainless Steel (Schedule 40)

Amperage by Voltage (3Ø Phase)

208 VAC240 VAC380 VAC415 VAC440 VAC480 VAC600 VAC
166.50 A 157.20 A 91.20 A 83.50 A 78.70 A 72.20 A 57.70 A

Plumbing Connection Sizes

Water Inlet 1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS)
Steam Outlet 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS
Safety Valve 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body.
Drain 1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS)

Options

Spare Parts Package Includes 18-Month Warranty (12-Month Standard)
(2) Electric Heaters and (2) Heater Gaskets
(2) Sight Glass Tubes and (4) Washers
(1) Pressure Control
(1) Contactor
Single Service Transformer Supplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC1Ø for the controls; with the option, only the one (1) primary high voltage supply is required.
Manual Low Water Reset5 Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production.
Portable Mounting Includes Wheels
Push Handle
Single Service Transformer Option
Water Feed Booster Pump The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm.
  • 1 Each Electro-Steam™ electric steam generator requires two (2) power supplies: One (1) primary high voltage supply and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate only one (1) customer specific high voltage supply for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
  • 2 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
  • 3 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
  • 4 Wetted Surfaces.
  • 5 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply remove the jumper wire from the back of the Reset Button.