LB 40-60 Electric Steam Generators
LB-50 (C) 50 Kilowatt (kW) Electrical Power Rating Electric Steam Generator
Standard Features
| ASME Certified | High Pressure Safety Reset |
| UL Listed and labeled under UL 834 | Dual Pressure Controls (UL 353) |
| Low Level Cut-Off (LLCO) (UL 353) | Safety Relief Valve possessing the ASME V Mark |
Included Options (Standard for Cleaners)
| Heavy-Duty Steam Gun (10 ft Hose) | Solution Bucket |
Recommended Options (Non-Standard)
| Portable Mounting | Single Service Transformer |
| Spare Parts Package | Solution Mixer |
Specifications
| Brand | Electro-Steam™ |
|---|---|
| Variant | Cleaner |
| Electrical Power | 50 kW |
| Power Supply Voltage1 | 208 VAC, 230 VAC, 380 VAC, 415 VAC, 440 VAC, 480 VAC, 600 VAC |
| Phase | 3 |
| Frequency | 50 Hz, 60 Hz |
| Boiler Horse Power | 5.0 bhp |
| Steam Capacity2 | 172.5 lb/hr (78.24 kg/hr) |
| Water Consumption | 20.67 gal/hr (78.24 L/hr) |
| Gross British Thermal Units (BTU) Output | 167,377 Btu/hr |
| Maximum Boiler Pressure | 100 psi |
| Operating Pressure | 0 to 85 psi |
| Note for Operating Pressure | Factory Set at 85 psi |
| Maximum Boiler Capacity | 15 gal |
| Boiler Fill Capacity | 11 gal |
| Boiler Material3 | Carbon Steel |
| Cabinet Material | 304 Stainless Steel |
| Plumbing Material | Brass (Schedule 40), Carbon Steel (Schedule 40) |
Amperage by Voltage (3Ø Phase)
| 208 VAC | 240 VAC | 380 VAC | 415 VAC | 440 VAC | 480 VAC | 600 VAC |
|---|---|---|---|---|---|---|
| 138.80 A | 131.00 A | 76.00 A | 69.60 A | 65.60 A | 60.10 A | 48.10 A |
Plumbing Connection Sizes
| Water Inlet | 1/2" NPT (National Pipe Thread) (Female) - Y-Strainer, Brass |
|---|---|
| Steam Outlet | 1/4" NPT (National Pipe Thread) Union - Gun Connection |
| Safety Valve | 3/4" NPT (National Pipe Thread) (Female) - Safety Valve, Brass |
| Drain | 1" National Pipe Thread (NPT) (Female) - Ball Valve, Brass |
Included Options
| Heavy-Duty Steam Gun | Supplied standard with all LB Cleaner Models that are 40 kW or greater. The Heavy-Duty Steam Gun includes an adjustable solution valve to siphon a chemical solution from a reservoir at an adjustable flow rate. This chemical solution mixes with the discharging steam before exiting the gun. The standard attached Steam/Detergent Hose length is 10 ft; additional lengths are available upon request. (Sized in 10 ft increments) |
|---|---|
| Heat Resistant Gloves | Supplied standard with all Cleaner Models. Heat Resistant Gloves must be worn while operating/handling the steam gun. |
| Solution Bucket | Supplied standard with all Cleaner Models. The Solution Bucket hangs off the side of the steam generator and holds the chemical solution for the steam gun; it is strategically positioned for the steam gun to easily siphon from during operation. |
Options
| Spare Parts Package Includes | 18-Month Warranty (12-Month Standard) (2) Electric Heaters and (2) Heater Gaskets (2) Sight Glass Tubes and (4) Washers (1) Pressure Control (1) Contactor |
|---|---|
| Single Service Transformer | Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. |
| Manual Low Water Reset4 | Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. |
| Portable Mounting Includes | Wheels Push Handle Single Service Transformer Option |
| Water Feed Booster Pump | Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. |
More Options
| Solution Mixer | Solution Mixer attaches to the Solution Bucket; it automatically keeps the solution bucket full, while mixing a consistent ratio of solution and water. |
|---|---|
| Flare Nozzle | Nozzle attachment for the Heavy-Duty Steam Gun that concentrates the flow of steam into a flat jet. |
- 1 Each Electro-Steam™ electric steam generator requires two (2) power supplies: One (1) primary high voltage supply and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate only one (1) customer specific high voltage supply for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
- 2 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
- 3 Wetted Surfaces
- 4 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply plug the two attached wires into the PC-Board terminals labeled "Reset".